主管:国家卫生健康委员会
主办:国家卫生健康委医院管理研究所
中国科技核心期刊(中国科技论文统计源期刊)
中国科学引文数据库(CSCD)核心库期刊
《中文核心期刊要目总览》核心期刊

中国护理管理 ›› 2026, Vol. 26 ›› Issue (4): 524-529.doi: 10.3969/j.issn.1672-1756.2026.04.009

• 论著 • 上一篇    下一篇

改良版信息安全行为测量量表的汉化及信度效度检验

赵红妃 袁晓烨 潘荣丽 吕艾芹   

  1. 山东大学护理与康复学院,250100 济南市(赵红妃,潘荣丽);山东省口腔医院(山东大学口腔医院)护理部(袁晓烨);医疗事业部(吕艾芹)
  • 出版日期:2026-04-15 发布日期:2026-04-15
  • 通讯作者: 吕艾芹,博士,主任护师,医疗事业部部长,E-mail:Aiqin@sdu.edu.cn
  • 作者简介:赵红妃,硕士在读
  • 基金资助:
    山东大学一般横向项目(1350023012)

Translation and validation of the Chinese version of the Modified Information Security Behavior Measurement Scale

ZHAO Hongfei, YUAN Xiaoye, PAN Rongli, LYU Aiqin   

  1. School of Nursing and Rehabilitation, Shandong University, Jinan, 250100, China
  • Online:2026-04-15 Published:2026-04-15
  • Contact: E-mail:Aiqin@sdu.edu.cn

摘要: 目的:汉化改良版信息安全行为测量量表并检验其在护士群体中的信度及效度,为国内护士信息安全行为评估提供工具。方法:经源量表作者授权后,基于Brislin翻译模型完成量表翻译、回译、跨文化调适及预调查,形成中文版。2024年10月—12月采用便利抽样法,选取山东省、河南省8家医院823名护士进行信度、效度检验。结果:中文版量表包含3个维度、18个条目,条目内容效度指数为0.875~1.000,量表水平的内容效度指数为0.973。探索性因子分析提取4个公因子,累计方差贡献率为57.353%;验证性因子分析模型拟合指数χ2/df=3.881、RMSEA=0.084、CFI=0.904、NFI=0.876、GFI=0.880。量表总的Cronbach’s α系数为0.854,重测信度为0.983,折半信度为0.754。结论:中文版改良版信息安全行为测量量表信度、效度良好,可作为评估国内护士信息安全行为的有效工具。

关键词: 护士;信息安全;安全行为;信度;效度

Abstract: Objective: To translate the Modified Information Security Behavior Measurement Scale, and to verify its reliability and validity among nurses in China, so as to provide a tool for assessing information security behavior of Chinese nurses. Methods: After obtaining the authorization from the author of the original scale, the translation, back-translation, cross-cultural adaptation and pre-survey were completed based on the Brislin translation model. The validity and reliability of the Chinese version of the scale was assessed among 823 nurses from 8 hospitals in Shandong province and Henan province through convenience sampling from October to December 2024. Results: The Chinese version of the Modified Information Security Behavior Measurement Scale has three dimensions with 18 items. The I-CVI of the scale ranged from 0.875 to 1.000, and S-CVI was 0.973. Exploratory factor analysis extracted 4 common factors, with a cumulative variance contribution rate of 57.353%. The final model fit indices of confirmatory factor analysis were as follows: χ2/df=3.881, RMSEA=0.084, CFI=0.904, NFI=0.876, GFI=0.880. The Cronbach's α coefficient of the total scale was 0.854, the test-retest reliability was 0.983, and the split-half reliability was 0.754. Conclusion: The Chinese version of the Modified Information Security Behavior Measurement Scale has good reliability and validity, and can be used as an effective tool for evaluating the information security behavior of nurses in China.

Key words: nurse; information security; security behavior; reliability; validity

中图分类号:  R47;R197