中国护理管理 ›› 2019, Vol. 19 ›› Issue (12): 1800-1805.doi: 10.3969/j.issn.1672-1756.2019.12.009

• 论 著 • 上一篇    下一篇

自体动静脉内瘘穿刺风险评估表的编制及信度效度检验

蒲丛珊 沙丽艳 张嵘之   

  1. 大连医科大学附属第二医院护理部,116021 辽宁省(蒲丛珊,沙丽艳);血液透析室(张嵘之)
  • 出版日期:2019-12-15 发布日期:2019-12-15
  • 通讯作者: 张嵘之,硕士,副主任护师,护士长,E-mail:zhangrongzi000@163.com
  • 作者简介:蒲丛珊,硕士在读,护师
  • 基金资助:
    辽宁省科学技术计划项目(2017225041)

Reliability and validity of the autologous Arteriovenous Fistula puncture risk assessment scale

PU Congshan, SHA Liyan, ZHANG Rongzhi   

  1. Nursing Department, The Second Hospital of Dalian Medical University, Dalian, Liaoning province, 116021, China
  • Online:2019-12-15 Published:2019-12-15
  • Contact: E-mail:zhangrongzi000@163.com

摘要: 目的:编制自体动静脉内瘘穿刺风险评估表,并检验其信度、效度。方法:依据前期构建的自体动静脉内瘘穿刺风险因素评估指标体系编制评估表,咨询5名专家及进行预调查后,选取大连市某三级甲等医院血液透析中心的198名患者进行调查,评价该表的信度、效度并根据调查结果构建ROC曲线,得出诊断界值。结果:最终形成包含4个维度24个条目的自体动静脉内瘘穿刺风险评估表,探索性因子分析提取4个公因子,累计方差贡献率70.484%,所有条目因子载荷均>0.4,评估表条目水平的内容效度指数(I-CVI)为0.866~1.000,总体水平的内容效度指数(S-CVI)为0.942,总评估表的Cronbach’s?α系数为0.823,重测信度为0.783,ROC曲线面积为0.813,标准误为0.070,95%置信区间为(0.677,0.950),具有统计学意义(P=0.001)。当得分为10分时其约登指数最大,约登指数为0.493,对评估表预测的灵敏度为70.00%,特异度为79.30%,该评估表的诊断界值为10分。结论:本研究编制的自体动静脉内瘘评估表在临床工作中具有现实意义,初步检验其具有良好的信度、效度,可作为护士自体动静脉内瘘穿刺前的评估工具。

关键词: 自体动静脉内瘘;穿刺风险;测评工具;信度;效度

Abstract: Objective: To establish the Arteriovenous Fistula puncture risk assessment scale and test its reliability and validity. Methods: The assessment scale was first developed according to the pre-established indicator system for evaluating autologous Arteriovenous Fistula puncture risk. Then after consulting 5 experts and a pilot study, 198 patients from a hemodialysis center of a third-grade hospital in Dalian were selected for investigation and evaluation. The reliability and validity of the assessing tool and the ROC curve based on the survey results were obtained to figure out the diagnostic boundary value. Results: Finally, the Arteriovenous Fistula puncture risk assessment form with 4 dimensions and 24 items was established. 4 common factors were extracted using exploratory factor analysis with the accumulated variance contribution rate being 70.484%, and the factor loads of all items were beyond 0.4. The content validity index of items (I-CVI)was 0.866-1.000 and the content validity index of scale (S-CVI) was 0.942. The Cronbach's α coefficient of the scale was 0.823, and the test-retest reliability was 0.783. The ROC curve area was 0.813 and the standard error was 0.070 with the 95% confidence interval being (0.677, 0.950), which was statistically significant (P=0.001). The Yoden index reached the highest of 0.493 when the score was 10. The predicted sensitivity of the scale was 70.00% and the specificity was 79.30%. The diagnostic threshold of the evaluation scale was 10 points. Conclusion: The self-designed Arteriovenous Fistula evaluation scale has practical significance for clinical work. With a good reliability and validity in the primary test, it can be used as an assessment tool for nurses before autologous Arteriovenous Fistula puncture.

Key words: Arteriovenous Fistula; puncture risk; evaluation tool; reliability; validity