主管:国家卫生健康委员会
主办:国家卫生健康委医院管理研究所
中国科技核心期刊(中国科技论文统计源期刊)
中国科学引文数据库(CSCD)核心库期刊
《中文核心期刊要目总览》核心期刊

中国护理管理 ›› 2020, Vol. 20 ›› Issue (4): 506-512.doi: 10.3969/j.issn.1672-1756.2020.04.007

• 特别策划·循证护理研究进展及剖析 • 上一篇    下一篇

我国护理临床实践指南的质量评价

靳英辉 王云云 高锦萍 张菁 李紫梦   

  1. 武汉大学中南医院循证与转化医学中心,430071(靳英辉,王云云);武汉大学循证与转化医学中心(靳英辉,王云云);山西医科大学护理学院(高锦萍);武汉大学第一临床学院(张菁);天津中医药大学护理学院(李紫梦)
  • 出版日期:2020-04-15 发布日期:2020-04-15
  • 通讯作者: 王云云,硕士,E-mail:13545027094@163.com E-mail:E-mail:jinyinghui0301@163.com
  • 作者简介:靳英辉,博士,副主任,E-mail:jinyinghui0301@163.com
  • 基金资助:
    中央高校基本科研业务费专项资金资助(2042019kf0330)

Quality evaluation of nursing clinical practice guidelines in China

JIN Yinghui, WANG Yunyun, GAO Jinping, ZHANG Jing, LI Zimeng   

  1. Center for Evidence-Based and Translational Medicine, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
  • Online:2020-04-15 Published:2020-04-15
  • Contact: E-mail:13545027094@163.com E-mail:E-mail:jinyinghui0301@163.com

摘要: 目的:评价中国护理领域临床践指南的质量。方法:由2名研究人员检索国内外数据库,包括PubMed、CINAHL、Web of Science、中国知网(CNKI)、中国生物医学文摘数据库(CBM)、万方数据库(WanFang Data)、维普中文科技期刊数据库(VIP)及相关网站,检索时间为建库至2019年7月31日,采用中国临床实践指南评价体系(AGREE-China)、RIGHT清单及指南实施性评价工具(GLIA 2.0)对纳入指南进行质量评价。结果:共纳入20篇指南, AGREE-China平均得分为(71.71±13.16)分;RIGHT清单条目报告率在0和100.0%之间;实施性评价结果中单篇指南符合率最高为100.0%,最低为60.0%。结论:中国护理临床实践指南的总体质量较好,但在有效性/安全性、自主与利益冲突类型等方面的报告仍较为欠缺。

关键词: 护理临床实践指南;质量评价;中国护理临床实践指南评价体系;RIGHT清单;指南实施性评价工具

Abstract: Objective: To evaluate the quality of clinical nursing practice guidelines in China. Methods: Two researchers searched domestic and foreign databases, including PubMed, CINAHL, Web of Science, CNKI, China Biomedical Abstracts Database (CBM), Wanfang Database, VIP Chinese Sci-tech Journals Database (VIP) and related websites from inception until July 31, 2019. The quality of the included guidelines was evaluated by using the evaluation tool for Chinese clinical practice guidelines (AGREE-China), the RIGHT list and the implementation evaluation tool for guidelines (GLIA 2.0). Results: A total of 20 guidelines were included. The average score of AGREE-China was 71.71 ±13.16. The overall reporting rates of the RIGHT list were between 0 and 100.0%. In the results of implementation evaluation, the highest coincidence rate of a single guideline was 100.0%, and the lowest was 60.0%. Conclusion: The overall quality of Chinese nursing clinical practice guidelines is good, but there are few reports on effectiveness / safety, autonomy and types of conflict of interest.

Key words: clinical practice guideline; quality evaluation; AGREE-China; RIGHT list; implementation evaluation tools for guidelines

中图分类号: 

  • R47