主管:国家卫生健康委员会
主办:国家卫生健康委医院管理研究所
中国科技核心期刊(中国科技论文统计源期刊)
中国科学引文数据库(CSCD)核心库期刊
《中文核心期刊要目总览》核心期刊

中国护理管理 ›› 2026, Vol. 26 ›› Issue (11): 1698-1703.doi: 10.3969/j.issn.1672-1756.2026.11.018

• 护理质量 • 上一篇    下一篇

《预防血管内导管相关血流感染过程质控工具包》应用效果调查

尚文涵 刘艳存 李晴 龚喜燕 么莉   

  1. 国家卫生健康委医院管理研究所护理管理与康复研究部,100044 北京市(尚文涵,么莉);阜外华中心血管病医院结构性心脏病一病区(刘艳存);济宁市第一人民医院心内科(李晴);自贡市第一人民医院甲乳外科(龚喜燕)
  • 出版日期:2026-11-15 发布日期:2026-11-15
  • 通讯作者: 么莉,副主任护师,护理管理与康复研究部主任,E-mail:yaoli@niha.org.cn
  • 作者简介:尚文涵,硕士,副研究员

Investigation on the application effect of the Process-based Quality Control Toolkit for the Prevention of Intravascular Catheter-Related Bloodstream Infections

SHANG Wenhan, LIU Yancun, LI Qing, GONG Xiyan, YAO Li   

  1. Department of Nursing Management and Rehabilitation Research, National Institute of Hospital Administration, National Health Commission, Beijing, 100044, China
  • Online:2026-11-15 Published:2026-11-15
  • Contact: E-mail:yaoli@niha.org.cn

摘要: 目的:调查《预防血管内导管相关血流感染过程质控工具包》(以下简称《工具包》)的应用效果,为医疗机构血管内导管相关血流感染精细化过程管控提供依据。方法:采用便利抽样法,于2024年4月选取全国124家医院为研究对象,分析《工具包》应用前后重点操作执行情况与感染指标监测结果。结果:《工具包》应用后,中心静脉导管(Central Venous Catheter,CVC)相关血流感染发生率由0.22‰降至0.16‰,差异具有统计学意义(P<0.05);经外周静脉穿刺中心静脉置管相关血流感染发生率干预前后均为0.08‰。最大化无菌屏障、导管位置确定、输液装置更换、冲封管等维度多项操作执行率明显提升,差异有统计学意义(P<0.05),但CVC置管最大化无菌屏障相关条目、各类推荐性防控条目落实水平整体偏低。东、中、西部地区绝大多数血管导管防控措施执行情况差异无统计学意义(P>0.05)。结论:应用《工具包》可提升临床操作规范化水平,降低CVC相关血流感染发生风险。后续临床需要重点强化CVC置管最大化无菌屏障措施的质控管理,并推进各类推荐性防控条目落地执行。

关键词: 导管相关血流感染;过程质控;工具包;静脉治疗;护理质量;患者安全

Abstract: Objective: To investigate the application effect of the Process-based Quality Control Toolkit for the Prevention of Intravascular Catheter-Related Bloodstream Infections, and to provide evidence for refined process management and control of intravascular Catheter-Related Bloodstream Infections in medical institutions. Methods: A convenience sampling method was adopted, and 124 hospitals across China were enrolled as research subjects in April 2024. Key practice compliance and surveillance outcomes of infection indicators before and after the implementation of the toolkit were analyzed. Results: After toolkit implementation, the incidence of CVC-related bloodstream infection decreased from 0.22‰ to 0.16‰, with a statistically significant difference (P<0.05). The incidence of PICC-related bloodstream infection remained at 0.08‰ both before and after intervention, showing no obvious change. The compliance rates of multiple practices including maximum sterile barrier protection, catheter position confirmation, infusion set replacement, and flushing and locking procedures were significantly improved (P<0.05). Nevertheless, compliance with items concerning maximum sterile barrier protection for CVC insertion and various recommended prevention and control measures remained generally low. No statistically significant differences were observed in the implementation of most vascular catheter prevention and control measures among the eastern, central and western regions (P>0.05). Conclusion: Application of the toolkit can improve the standardization of clinical practices and reduce the risk of CVC-related bloodstream infections. Subsequent clinical quality control management should focus on strengthening maximum sterile barrier protection during CVC insertion and promoting the implementation of various recommended prevention and control items.

Key words: Catheter-Related Bloodstream Infection; process quality control; toolkit; intravenous therapy; nursing quality; patient safety

中图分类号:  R47;R197