主管:国家卫生健康委员会
主办:国家卫生健康委医院管理研究所
中国科技核心期刊(中国科技论文统计源期刊)
中国科学引文数据库(CSCD)核心库期刊
《中文核心期刊要目总览》核心期刊

中国护理管理 ›› 2020, Vol. 20 ›› Issue (3): 474-479.doi: 10.3969/j.issn.1672-1756.2020.03.032

• 专科管理 • 上一篇    下一篇

早产儿PICC腔内心电图准确定位P波比例的比较分析

杨丽娟 刘安诺 徐兵 陈娜   

  1. 安徽医科大学护理学院儿科教研室,230032 合肥市(杨丽娟,刘安诺);蚌埠医学院第一附属医院儿科(杨丽娟,徐兵,陈娜)
  • 出版日期:2020-03-15 发布日期:2020-03-15
  • 通讯作者: 刘安诺,博士,教授,儿科护理教研室主任,E-mail:183806841@qq.com
  • 作者简介:杨丽娟,硕士在读,主管护师,护士长
  • 基金资助:
    安徽省自然科学基金项目(1808085MH277);蚌埠医学院自然科学基金重点项目(BYKY1431ZD)

Clinical study on P-wave ratio of the ECG-aided tip accurate localization of Peripherally Inserted Central Catheter in premature infants

YANG Lijuan, LIU Annuo, XU Bing, CHEN Na   

  1. Nursing School of Anhui Medical University, Hefei, 230032, China
  • Online:2020-03-15 Published:2020-03-15
  • Contact: E-mail:183806841@qq.com

摘要: 目的:分析早产儿PICC腔内心电图准确定位的P波比例及体位改变对P波比例的影响。方法:将2018年1月至2019年3月入住蚌埠市某三级甲等医院新生儿监护室行PICC置管的289例早产儿作为研究对象。置管成功后将患儿肢体摆放于体位1与体位2(自然体位)时分别进行腔内心电图定位,PICC固定后拍摄体位2时胸部X片。比较两种体位腔内心电图P波比例,研究体位2时P波比例与导管尖端位置的关系。结果:经贵要静脉、肘正中静脉、腋静脉、头静脉、颞浅静脉置入PICC时,两种体位时腔内心电图P波比例比较差异有统计学意义(P<0.01);导管尖端位于T4-T6时,P波比例95%CI为0.64~0.67;腔内心电图定位敏感性与特异性分别是94.9%与100.0%。结论:早产儿PICC腔内心电图定位具有较高的敏感性与特异性,特征性P波比例在0.64~0.67之间时,PICC导管尖端有95%的可能处于最佳位置,体位改变影响早产儿PICC腔内心电图定位P波比例。

关键词: 腔内心电图;P波比例;经外周静脉穿刺中心静脉置管;早产儿

Abstract: Objective: To investigate P-wave ratio of the ECG-aided tip accurate localization and the effect of body position change on P-wave ratio of PICC cavity electrograph in premature infants. Methods: 289 premature infants who were admitted to the neonatal intensive care unit of a hospital in Bengbu from January 2018 to March 2019 and met the indications of PICC catheterization were selected as the research subjects. After placement the catheter, the child’s limb was placed in position 1 and position 2 (natural position) respectively to receive ECG-aided tip localization. Chest X-ray was taken at the position 2 after fix the PICC. The ratio of P-wave in the ECG at the two positions was compared, and the relationship between the P-wave ratio and the tip position was studied at position 2. Results: When the PICC was placed in the basilica vein, elbow median vein, iliac vein, cephalic vein, and superficial vein, the difference in the P-wave ratio of the ECG in the two positions was statistically significant (P<0.01). The 95% confidence interval for P-wave ratio was 0.64-0.67 when the tip of PICC catheter was at T4-T6. The sensitivity and specificity of the ECG-aided tip localization were 94.9% and 100.0%. Conclusion: The ECG-aided tip localization in premature infants has high sensitivity and specificity. When the P-wave ratio is between 0.64-0.67, the tip of PICC catheter is 95% likely to be in the best position. The position change is the influence factor of the inner electrogram positioning of PICC cavity in premature infants.

Key words: electrocardiography; P-wave ratio; Peripherally Inserted Central Catheter; premature infants

中图分类号: 

  • R47