主管:国家卫生健康委员会
主办:国家卫生健康委医院管理研究所
中国科技核心期刊(中国科技论文统计源期刊)
中国科学引文数据库(CSCD)核心库期刊
《中文核心期刊要目总览》核心期刊

中国护理管理 ›› 2024, Vol. 24 ›› Issue (9): 1347-1350.doi: 10.3969/j.issn.1672-1756.2024.09.013

• 肿瘤护理专题 • 上一篇    下一篇

MD安德森症状评估量表急性白血病模块的编制及信度和效度检验

王菲菲 孟利敏 曾小青 张文坚 祁欢 曾庆威 郭秀芳 吴学成 林栋美   

  1. 赣南医科大学护理学院,341000 江西省赣州市(王菲菲,孟利敏,祁欢,郭秀芳,吴学成,林栋美);深圳市宝安区石岩人民医院(王菲菲);赣南医科大学第一附属医院(曾小青);广州市第一人民医院(张文坚);深圳市龙岗区妇幼保健院(曾庆威)
  • 出版日期:2024-09-15 发布日期:2024-09-15
  • 通讯作者: 林栋美,博士,副教授,副院长,E-mail:Lindong_mei5678@sina.com
  • 作者简介:王菲菲,硕士在读
  • 基金资助:
    国家自然科学基金(72164001)

Development and test of reliability and validity of MD Anderson Symptom Inventory-Acute Leukemia Module

WANG Feifei, MENG Limin, ZENG Xiaoqing, ZHANG Wenjian, QI Huan, ZENG Qingwei, GUO Xiufang, WU Xuecheng, LIN Dongmei   

  1. School of Nursing, Gannan Medical University, Ganzhou, Jiangxi province, 341000, China
  • Online:2024-09-15 Published:2024-09-15
  • Contact: E-mail:Lindong_mei5678@sina.com

摘要: 目的:编制MD安德森症状评估量表急性白血病模块,并检验其信度和效度。方法:通过文献回顾、半结构式访谈、德尔菲专家函询和患者预调查形成预量表,选取235例成人急性白血病患者进行临床调查,检验其信度和效度。结果:MD安德森症状评估量表急性白血病模块共25个条目,包括19个症状评估条目和6个症状对日常生活的困扰条目。内容效度结果显示,I-CVI和S-CVI均大于0.8。验证性因子分析结果显示,χ2/df=2.230,RMSEA=0.072,GFI=0.976,CFI=0.955,IFI=0.956,NFI=0.923,TLI=0.915,模型拟合结果良好,具有良好的结构效度。MD安德森症状评估量表急性白血病模块总量表的Cronbach’s?α系数为0.941,急性白血病模块的Cronbach’s?α系数为0.707。结论:MD安德森症状评估量表急性白血病模块具有较好的信度和效度,可作为急性白血病患者症状的评估工具。

关键词: 急性白血病;MD安德森症状评估量表;症状;评估工具;信度;效度

Abstract: Objective: To develop MD Anderson Symptom Inventory-Acute Leukemia Module and assess its reliability and validity. Methods: A preliminary scale was developed through literature review, semi-structured interviews, Delphi expert consultation, and patient pre-surveys. A clinical investigation involving 235 adult patients with Acute Leukemia was conducted to assess its reliability and validity. Results: MD Anderson Symptom Inventory-Acute Leukemia Module consists of 25 items, including 19 symptom items and 6 items assessing the interference of symptoms with daily life. The content validity results indicate that both the I-CVI and S-CVI are greater than 0.8. The results of confirmatory factor analysis showed that the revised model suitability indexes were χ2/df=2.230, RMSEA=0.072, GFI=0.976, CFI=0.955, IFI=0.956, NFI=0.923, TLI=0.915. The Cronbach's α coefficient for the total MD Anderson Symptom Inventory-Acute Leukemia Module is 0.941, while the Cronbach's α coefficient for the Acute Leukemia Module is 0.707. Conclusion: MD Anderson Symptom Inventory-Acute Leukemia Module developed in this study has demonstrated good reliability, and validity. It is an accurate and objective tool for assessing symptoms of Acute Leukemia patients.

Key words: Acute Leukemia; MD Anderson Symptom Inventory; symptom; assessment tools; reliability; validity