术中低体温护理质量指标体系的构建

周羽 朱琳 柳露 荣蓉 卢秀英   

  1. 成都医学院,610500 成都市(周羽);四川省肿瘤临床医学研究中心,四川省肿瘤医院研究所,四川省癌症防治中心,电子科技大学附属医院手术麻醉科(朱琳,柳露,荣蓉,卢秀英)
  • 出版日期:2024-04-15 发布日期:2024-04-15
  • 通讯作者: 卢秀英,硕士,主任护师,科护士长,E-mail:185472064@qq.com
  • 作者简介:周羽,硕士
  • 基金资助:
    四川省干部保健科研项目(川干研 2022-801)

Construction of evidence-based index system of Intraoperative Hypothermia nursing quality

ZHOU Yu, ZHU Lin, LIU Lu, RONG Rong, LU Xiuying   

  1. Chengdu Medical University, Chengdu, 610500, China
  • Online:2024-04-15 Published:2024-04-15
  • Contact: E-mail:185472064@qq.com

摘要: 目的:构建科学、可靠、具有可操作性的术中低体温护理质量指标体系,为护理管理者进行术中低体温护理质量评价提供参考。方法:基于“结构-过程-结果”三维质量结构模型,通过循证文献分析与小组讨论初步构建术中低体温护理质量指标,采用德尔菲法对26名专家进行函询,采用优序图法确定各层级指标权重。结果:术中低体温护理质量指标体系包括3项一级指标、4项二级指标、12项三级指标;两轮函询专家积极系数分别为100.0%、96.3%,专家权威系数分别为0.92、0.93,肯德尔和谐系数为0.12~0.23(P<0.05)。结论:本研究构建的术中低体温护理质量指标具有专科特色,且指标体系具有科学性及可靠性,对量化临床术中低体温护理质量具有一定的指导意义。

关键词: 术中低体温;质量指标;护理质量;三维质量结构模型;循证护理;德尔菲法

Abstract: Objective: To construct a scientific, reliable and operable set of Intraoperative Hypothermia (IH) nursing quality index system, in order to provide a reference for nursing managers to evaluate the IH nursing quality. Methods: Donabedian's "structure-process-outcome" three-dimensional quality structure model was used to preliminarily construct IH nursing quality indicators through evidence-based literature analysis and group discussion, and 26 experts were consulted by Delphi method, and the index weights at each level were determined by the preferential sequence diagram method. Results: There were 3 first-level indicators, 4 second-level indicators and 12 third-level indicators of the index system. The positive coefficients of experts in the two rounds consultation were 100.0% and 96.3%, the coefficients of expert authority were 0.92 and 0.93 respectively, and the Kendall harmony coefficients were from 0.12 to 0.23 (P<0.05). Conclusion: The IH nursing quality index constructed in this study has specialized characteristics, and the research results are scientific and reliable, which has certain guiding significance for quantifying the clinical IH nursing quality.

Key words: Intraoperative Hypothermia; quality indicator; nursing quality; three-dimensional quality structure model; evidence-based nursing; Delphi method

中图分类号:  R47;R197