主管:国家卫生健康委员会
主办:国家卫生计生委医院管理研究所
中国科学引文数据库(CSCD)来源期刊
中国科技论文统计源期刊 中国科技核心期刊
《中文核心期刊要目总览》入选期刊

Chinese Nursing Management ›› 2026, Vol. 26 ›› Issue (11): 1698-1703.doi: 10.3969/j.issn.1672-1756.2026.11.018

• Nursing Quality • Previous Articles     Next Articles

Investigation on the application effect of the Process-based Quality Control Toolkit for the Prevention of Intravascular Catheter-Related Bloodstream Infections

SHANG Wenhan, LIU Yancun, LI Qing, GONG Xiyan, YAO Li   

  1. Department of Nursing Management and Rehabilitation Research, National Institute of Hospital Administration, National Health Commission, Beijing, 100044, China
  • Online:2026-11-15 Published:2026-11-15
  • Contact: E-mail:yaoli@niha.org.cn

Abstract: Objective: To investigate the application effect of the Process-based Quality Control Toolkit for the Prevention of Intravascular Catheter-Related Bloodstream Infections, and to provide evidence for refined process management and control of intravascular Catheter-Related Bloodstream Infections in medical institutions. Methods: A convenience sampling method was adopted, and 124 hospitals across China were enrolled as research subjects in April 2024. Key practice compliance and surveillance outcomes of infection indicators before and after the implementation of the toolkit were analyzed. Results: After toolkit implementation, the incidence of CVC-related bloodstream infection decreased from 0.22‰ to 0.16‰, with a statistically significant difference (P<0.05). The incidence of PICC-related bloodstream infection remained at 0.08‰ both before and after intervention, showing no obvious change. The compliance rates of multiple practices including maximum sterile barrier protection, catheter position confirmation, infusion set replacement, and flushing and locking procedures were significantly improved (P<0.05). Nevertheless, compliance with items concerning maximum sterile barrier protection for CVC insertion and various recommended prevention and control measures remained generally low. No statistically significant differences were observed in the implementation of most vascular catheter prevention and control measures among the eastern, central and western regions (P>0.05). Conclusion: Application of the toolkit can improve the standardization of clinical practices and reduce the risk of CVC-related bloodstream infections. Subsequent clinical quality control management should focus on strengthening maximum sterile barrier protection during CVC insertion and promoting the implementation of various recommended prevention and control items.

Key words: Catheter-Related Bloodstream Infection; process quality control; toolkit; intravenous therapy; nursing quality; patient safety

CLC Number: R47;R197